[HUDI-1493] Fixed schema compatibility check for fields. (#2350)

Some field types changes are allowed (e.g. int -> long) while maintaining schema backward compatibility within HUDI. The check was reversed with the reader schema being passed for the write schema.
This commit is contained in:
Prashant Wason
2020-12-29 17:02:21 -08:00
committed by GitHub
parent e33a8f733c
commit c6bf952332
2 changed files with 32 additions and 6 deletions

View File

@@ -296,7 +296,7 @@ public class TableSchemaResolver {
public static boolean isSchemaCompatible(Schema oldSchema, Schema newSchema) {
if (oldSchema.getType() == newSchema.getType() && newSchema.getType() == Schema.Type.RECORD) {
// record names must match:
if (!SchemaCompatibility.schemaNameEquals(oldSchema, newSchema)) {
if (!SchemaCompatibility.schemaNameEquals(newSchema, oldSchema)) {
return false;
}
@@ -329,9 +329,11 @@ public class TableSchemaResolver {
// All fields in the newSchema record can be populated from the oldSchema record
return true;
} else {
// Use the checks implemented by
// Use the checks implemented by Avro
// newSchema is the schema which will be used to read the records written earlier using oldSchema. Hence, in the
// check below, use newSchema as the reader schema and oldSchema as the writer schema.
org.apache.avro.SchemaCompatibility.SchemaPairCompatibility compatResult =
org.apache.avro.SchemaCompatibility.checkReaderWriterCompatibility(oldSchema, newSchema);
org.apache.avro.SchemaCompatibility.checkReaderWriterCompatibility(newSchema, oldSchema);
return compatResult.getType() == org.apache.avro.SchemaCompatibility.SchemaCompatibilityType.COMPATIBLE;
}
}